The Sentech refrigerant monitors are 'early warning' loss detection monitoring systems designed specifically for refrigerants. These environmental system IR-SNIF monitors are specialised refrigerant monitors that have been designed for applications such as comfort air, refrigeration and critical environment applications.
The IR-SNIF models are cost effective, self contained active air-draw sampling systems offereing highly reliable infrared-based performance with the flexibility to satisfy a wide range of continuous monitoring applications.
The monitors utilise NDIR [non-dispersive infrared] and pyroelectric [absorptive sensing] technology featuring multi-zone detection point capability from a single field-programmable self-contained metal enclosure featuring a unique built-in leak wait period that minimises nuisance false alarms.
Suitable applications for the Sentech Refrigeration Leak Monitors are:
- Supermarkets
- Refrigerated warehousing
- Industrial process cooling
- Sports arenas
- Agricultural process and stroage
| Comfort Air Applications |
Refrigerant Applicaitons |
Critical Environment Applicaitons |
- Office buildings
- Hospitals
- Schools & Universities
- Factories
- Government facilities
|
- Supermarkets
- Refrigerated warehousing
- Industrial process cooling
- Sports arenas
- Agricultural process and stroage
|
- Corporate data centres
- Telecom switching factilities
- Process control rooms
- Industrial robotic systems
- Medical diagnostic centres
- Clean rooms
|

IR-SNIF 1,2,3
|
|
IR-SNIF MCD
|
| Environmenatal systems single channel loss monitors |
|
Environmenatal systems multi channel loss monitors |
- Detects all Halogen based refrigerants
- Refrigerant type can be field cahnged without recalibration
- Continuous ditital display of system status
- Analogue output for remote monitoring
- System malfunction detection and indication
- Visual alarm indication
- Models are available to accommodate sampling points located up to 76 meters from the unit
- Fresh air inlet for automatic rezeroing
- Individually adjusted alarm point for each gas type being monitoried
|
|
- Detects all Halogen based refrigerants
- Refrigerant type can be field changed without calibration
- Continuous digital display of system status
- Analogue output for remote monitoring
- System malfunction detection and indication
- Visual alarm indication
- Models are available to accommodate sampling points located up to 76 meters from the unit
- Fresh air inlet for automatio rezeroing
- Individually adjusted alarm point for each gas type being monitored
|
Specifications
| |
IR-SNIF 1,2,3 |
IR-SNIF MCD |
| Sensitivity |
as low as 10 PPM |
as low as 1 PPM |
| Weight |
7.2 kg |
14.4 kg |
| Power requirements |
120/240 Volt 50/60 Hz |
120/240 Volt 50/60 Hz |
| Range |
0 to 1000 PPM |
0 to 1000 PPM |
| Alarm trip points |
|
|
| Low Alarm |
0 to 100% full scale |
0 to 100% full scale |
| Main Alarm |
0 to 100% full scale |
0 to 100% full scale |
| High Alarm |
0 to 100% full scale |
0 to 100% full scale |
| Operating environment range |
0°c to 50°c |
0°c to 50°c |
| Alarm Outputs |
Indicator Light
Alarm Relays with 4 Form C contacts (2 amps max)
|
Indicator Light
3 Alarm Relays, 1 Horn Control Relay each with
4 Form C contacts (amps max)
|