Process Instrumentation - Sales / Installation / Calibration

Process Instrumentation - Sales / Installation / Calibration

Calibration & Service

Calibration & Service

Pressure

Pressure

Gas Detection

Gas Detection

Sales, System Design, Installation & Calibration
a division of Aegis Safety Pty Ltd

Sales, System Design, Installation & Calibration

Techinspect is an instrumentation, gas detection, and electrical contracting company, with its head office located in Brisbane. Founded in 2004, Techinspect is a division of Aegis Safety Pty Ltd (a wholly Australian owned and run business) with a highly skilled workforce trained to provide quality service and products. Our operations cover everything from sales, system design and service to maintenance and installation. We are able to offer calibration services in our workshop located in Geebung or at your site by our on the road service team.

Download Company Profile
Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion
Our Suppliers include:

Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion

Additel - Pressure Gauges, Automated & Digital Pressure Calibrators, Process Calibrators / Honeywell - Portable & Fixed Gas Detection / Intech - Transmitters, Data Loggers, PLC multiplexers, Process Indicators, Microscan, SCADA & Recorders / Rhomberg - Pressure Gauges / Sentech - Refrigeration Monitors,

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring
Our Range of Products include:

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring

Automated & Digital Pressure Calibrators, Process & Loop Calibrators, Car Park Monitoring Systems from AmpControl & Honeywell Analytics, Sentech Refrigerant Leak Monitors, Rhomberg Pressure Gauges, Instrumentation - Temperature Monitoring Systems, PLC programming, SCADA, Data Loggers, Weather Stations and many more...

Calibration, System Design, Installation, Fault Finding
Our Services include:

Calibration, System Design, Installation, Fault Finding

With a dedicated temperature and pressure testing lab, Techinspect has all your calibration requirements covered. As well as calibrating portable equipment including portable gas detectors, pressure gauges, instrumentation at our workshop we provide on-site solutions for permanently installed systems including [but not limited to] car park gas detection, refrigerant leak monitors and temperature monitoring.

Contact Us for Pricing

12 Channel Controller

AmpControl 12 Channel ControllerAmpcontrol's 12 Channel System Controller is a compact unit designed to accept any sensor or transmitter that gives a 4-20mA output with relay outputs on board for alarm events and programmed response.

The 12 Channel Controller accepts inputs from any two or three wire sensor/transmitter combination that gives a 4-20mA output. Typical sensor/transmitter combinations include Ampcontrol detectors for combustible gas, oxygen, toxic gas, flame as well as temperature and humidty transmitters. 

The controller has twelve 4-20mA inputs, two 4-20mA outputs and four relay outputs for common Warn, Alarm, High Alarm and Fault conditions. Three push buttons, four LEDs and a sounder provide status and control functions.  

A two-line alpha-numeric display provides continuous status readouts of each monitored channel, with a choice of two user-configurable formats. A specific display mode shows all input readings and status simultaneously. 

Features
Electrical Specifications
Visual & Audible Specifications

  • Accommodates up to 12 gas detectors
  • Microprocessor controlled
  • Accepst input from combustible and toxic gas sensors, flame sensor or any 4-20mA device
  • Two-line alpha-numeric display
  • User friendly
  • Retians data on loss of power
  • Fully programmable from front panel
  • Built-in self diagnosis
  • Fan control logic
  • Software 'Voting Logic' output
  • Optiona RS485 Modbus® digital interface
  • Optional data and event logging

 

 Power Requirements
 [including options] Note: values  are of current are approximate
 240Vac, 50/60Hz, 125mA,    or
 110Vac, 50/60Hz, 250mA,    or
 24Vdc, 1.5A
 100mA internal
 200mA Aux output devices
 1200mA sensors
 Input Channels  12 
 Types of Input
 [one per channell]
 Note: with special auxiliary  junction box
 4-20mA, 24Vdc loop-powered sensors
 4-20mA, 3-wire sensors [24  16Vdc fixed] 
 Two-wire Fire/Flame Detection Units
 Outputs 
 [standard configuration]
 Common Fault Relay, Common Warn Relay 
 Common Alarm Relay and Common High Alarm Relay, SPDT, 7A,  240Vac/30Vdc
 Outputs
 [zone 4-20mA output board  option] Note: one output per zone
 Two Zone 0-20mA or 4-20mA source outputs into 600 Ohms [max]
 Outputs
 [auxiliary relay board option]  Note: one of each relay type per  zone
 Two Warn Relays and Two Alarm Relays, SPDT, 7A, 240Vac/30Vdc
 Outputs 
 [Individaul channel relay option] *
 Individual Warn RElays SPDT
 Individual Alarm Relays SPDT
 Individaul High Alarm Relays and Individaul Fault Relays SPDT, 7A,  240Vac/30Vdc
 Outputs
 [individual 4-20mA Channel output  option] **
 From four to Twelve, 4-20mA source outputs into 600 Ohms [max]
* Note: Tow external Twenty Four Channel RElay Decoder Drivers can be added to provide individaul Warn, Alarm, High Alarm  and Fault Relays. Up to six, Eight Way Relay Modules can be connected.
** Note: up to Twelve 4-20mA outputs can be added in blocks of 4 to an external panel.

 Liquid Crystal Display Backlit alphanumeric display indicates:
  • Channel
  • Status
  • Unit of measure
  • Substance/area measured
  • Previous minimum/maximum values
  • Channel output current
 Light Emitting Diodes:

 Indicate status of:

  • Power
  • Warn
  • Alarm 
  • Fault
 Electronic Buzzer:

 Audible Alarm for:

  • Warn
  • Alarm
  • Fault

Micro 4000 Gas Detection Controller

Micro 4000 Carpark Gas Detection ControllerThe Micro 4000 from AmpControl will accept inputs from any sensor/transmitter combination that will give a 4-20mA output. This versatile unit will also accept inputs directly from AmpControl's range of oxygen and combustible sensors along with two wire contact input devices.

Accpeing inputs from any sensor/transmitter combination that give a 4-20mA output the Micro 4000 also accepts inputs directly from Ampcontrol's range of combustible gas sensors, oxygen sensors and two wire contact input devices.  

This controller is an essential componed for any carpark gas detection monitoring system. If you want to control when and for how long your carpark exhaust fans operate the Mirco 4000 will suit your application.  

Available in: standard / HVAC SafeTguard / Flameproof

Features
Specifications

  • Microprocessor controlled  
  • Accepts inputs from combustibe land toxic gas sensors, flame sensors or any 4-20mA device
  • Two-line alpha numeric display
  • User friendly
  • Retains data on loss of power
  • Fully programmable from front
  • Built-in self diagnosis
  • Fan control logic option
  • Software 'Voting Logic' output
  • RS485 Modbus® digital interface  


 Performance  Specification 
 Dimensions  230mm x 177mm x 90mm
 Weight  2.4kg [including options]
 Housing Material  Poly Vinyl Chloride
 Environmental proctecion  IP54
 Operating Temperature range  -20ºC to 50ºC
 Operating Humidity range  0 - 100% Relative Humidity [non condensing]
 Outputs - 
 4-20mA output board option
 > four 4-20mA source outputs into 600 Ohms [max] 
     [note: 1 output per channel]
 Outputs - 
 Auxiliary Relay board option
 > Four Warn Relays, SPDT, 7A 240Vac/30Vdc
 > Four Alarm Relays, SPDT, 7A, 240Vac/30Vdc 
 Power Requirements
 [including options]
 Note: values of current are  approximage.
 > 240Vac, 50/60Hz, 125mA,      or
 > 110Vac, 50/60Hz, 250mA,      or
 > 24 16Vdc, 0.9A
 > Input Channels: Four
 > Types of Input [One per Channel]
 > Note: with special auxiliary junction box
 > Three-wire Bridge SEnsors [3 Watts maximum]
 > 4-20mA, 24Vdc loop-powered sensors
 > 4-20mA, 3-wire sensors [2-12Vdc adjustable]
 > 4-20mA, 3 wire sensors [24 16Vdc fixed]
 > Two-wire Fire/Flame Detection Units 
 > Outputs [standard configuration]: Common Fault Relay, SPDT, 7A,       240Vac/30Vdc
 > Common Warn Relay, SPDT, 7A, 240Vac/30Vdc
 > Common Alarm Relay, SPDT, 7A, 240Vac/30Vdc


iQguard Toxic

iQguard Toxic Gas Detection Sensor from AmpControlThe iQguard series of gas detectors provide high performance solution for a wide variety of industrial gas detection applications. By applying our wealth of experience and innovation in gas detector design, we have created a new generation of products serving environmental monitoring applications.

The iQguard series provide accurate, stable and repeatable gas detection measurements across a wide range of gas types.

iQguard Series options:

    Display and non-display models   
    Stainless steel or moulded PVC enclosure   
    Built in Modbus communications and ethernet options   
    SIL 2 compatible models available


Australian designed and manufactured  

 

Features
Specifications
Gas Types

  • Display or non-display models
  • Wide range of gas types
  • Stainless or moulded PVC enclosures
  • Swappable detector heads
  • Flexible configuration
  • Built-in relays
  • Modbus communications
  • Optional ethernet communications
  • Built in EMC RFI protection
  • SIL2 compatible
  • Compact & lightweight
  • Easy access connectors for installation of field wiring
  • Protected to IP66
  • Wide input power supply range
  • Easy to use
  • Simple sensor removal and replacement
  • On-board analysis function monitors sensor performance in display model

  

Measurement Technique
[all models] 
Electrochemical
Measurement Technology
[all models]
Long life electrochemical cells with condition monitoring
Measurement Ranges
[all models]
Gas Types
Configurable - please consult Techinspect for details
Standard as per table plus others on application
Standard as per table plus others on application
Measurement Characteristics
[all models]
Measurement accuracy
Drift [time]
Drift [temp]
+ 1.4% full scale at 25ºC
+ 5% full scale/year
Process Outputs
Non display current loop 4-20mA
Display current loop 4-20mA
Display version only
Digital RS485

4-20mA max loop load 680 Ohms max at 24V

4-20mA max loop load 960 Ohms max at 24V

Relay Outputs
Dual single pole change over relays
Rated carry current
Rated switching voltage

Display versions only

Connections
Non display model

2-wire for basic unit without graphical display 

 

Gas Type  Range [ppm*]  Operating Temperaure [deg C]
Ammonia  50  -20 to +40 
Ammonia   100   -20 to +40 
Carbon Monoxide  50   -20 to +50 
Carbon Monoxide  150   -20 to +50 
Carbon Monoxide  300   -20 to +50 
Chlorine  5   -20 to +50 
Hydrogen Sulphide  20   -20 to +50 
Nitric Oxide  100   -20 to +50 
Nitrogen Dioxide  20   -20 to +50 
Oxygen  25% v/v*   -20 to +50 
Sulphur Dioxide  20   -20 to +50 

 

Fixed Gas Detection

Techinspect has a variety of fixed gas detection and environmental monitoring systems. 

Ampcontrol's [formally Austech Instruments] fixed gas detection range includes the Micro 4000, 2400 series and 12 channel controllers. Their fixed gas detection range also includes the iQguard and Dguard for car park gas leak monitoring. 

Ampcontrol's 79-2500 and 79-3500 range of Exd group 2 certified flammable gas detectors are available in Infrared and Catalytic detection versions.

Our Technicians are competent in the installation and calibraion of Hazardous Area equipment.

Controllers

 

Sensors

 

   
Micro 4000 Carpark Gas Detection Controller   Sensors for Fixed Gas Detection systems        

 

Controllers

Our fixed gas detection controllers include the:

Micro 4000, 12 Channel and 2400 series from AmpControl.

Touchpoint Plus from Honeywell

 

Page 1 of 3
From our General Manager

We have all your Pressure, Instrumentation and Gas Detection in the one place.

Craig Colhoun

Craig Colhoun

General Manager

Would you like to know how we can help you?

Request more Information