Process Instrumentation - Sales / Installation / Calibration

Process Instrumentation - Sales / Installation / Calibration

Calibration & Service

Calibration & Service

Pressure

Pressure

Gas Detection

Gas Detection

Sales, System Design, Installation & Calibration
a division of Aegis Safety Pty Ltd

Sales, System Design, Installation & Calibration

Techinspect is an instrumentation, gas detection, and electrical contracting company, with its head office located in Brisbane. Founded in 2004, Techinspect is a division of Aegis Safety Pty Ltd (a wholly Australian owned and run business) with a highly skilled workforce trained to provide quality service and products. Our operations cover everything from sales, system design and service to maintenance and installation. We are able to offer calibration services in our workshop located in Geebung or at your site by our on the road service team.

Download Company Profile
Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion
Our Suppliers include:

Additel, Honeywell Analytics, Intech Instruments, Sentech Corporattion

Additel - Pressure Gauges, Automated & Digital Pressure Calibrators, Process Calibrators / Honeywell - Portable & Fixed Gas Detection / Intech - Transmitters, Data Loggers, PLC multiplexers, Process Indicators, Microscan, SCADA & Recorders / Rhomberg - Pressure Gauges / Sentech - Refrigeration Monitors,

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring
Our Range of Products include:

Gas Detection, Process Control, Pressure Gauges, Temperature Monitoring

Automated & Digital Pressure Calibrators, Process & Loop Calibrators, Car Park Monitoring Systems from AmpControl & Honeywell Analytics, Sentech Refrigerant Leak Monitors, Rhomberg Pressure Gauges, Instrumentation - Temperature Monitoring Systems, PLC programming, SCADA, Data Loggers, Weather Stations and many more...

Calibration, System Design, Installation, Fault Finding
Our Services include:

Calibration, System Design, Installation, Fault Finding

With a dedicated temperature and pressure testing lab, Techinspect has all your calibration requirements covered. As well as calibrating portable equipment including portable gas detectors, pressure gauges, instrumentation at our workshop we provide on-site solutions for permanently installed systems including [but not limited to] car park gas detection, refrigerant leak monitors and temperature monitoring.

Contact Us for Pricing

Additel ADT672 Digital Pressure Calibrators

Additel ADT672 differential pressure calibrator
With advanced microprocessor technology and state-of-the-art silicon sensors, Additel's ADT672 series precision pressure calibrators provide a pressure calibration solution for gauges, transmitters and switches in a wide pressure range. The ADT762 by Additel is a very portable device and cannot only measure pressure precisely with a built-in pressure sensor, but can also read the current or mV produced by the transducer, and can even supply an excitatio voltage to power sensors or transmitters during calibration.
 

 

In order to reach 0.025%FS accuracy over ranges to 10,000 psi [700 bar] and 0.1%FS accuracy over a range to 36,000 psi [2,500 bar], every silicon pressure sensor in our gauges has been specially aged, tested and screened before assembly. Additel's 672 series precision pressure calibrators are unmatched in performance and reliability.

 

Features
Pressure Guide
Video Demo

Pressure measurement uncertainty:

ADT672-02: 0.02% FS
ADT672-05: 0.05% FS
 
Pressure ranges to 40,000 psi (2,800 bar)
 
Measure mA with 0.02%RD + 0.9 μA accuracy
Measure V with 0.02%RD + 0.9 mV accuracy
 
Power transmitters during test using 24V loop supply
 
Pressure switch test
 
HART Communication capability
 
Advanced temperature compensation
 
Dual readout
 
Min/Max/Hold to capture changing measurements
 
Data logging
 
Large, easy to read display with 6-digit resolution 
 
Backlit display
 
Rechargeable battery or AC adapter
 
NIST traceable calibration with data (Included) 

  

Gauge Pressure for Additel's ADT672

ADT672 gauge pressure

 

 

 

 

 

 

 

 

 

 Absolute Pressue for Additel's ADT672

ADT672 absolute pressure

Compound Pressure for Additel's ADT672

ADT672 compound pressure

Differential Pressure for Additel's ADT672

ADT672 differential pressure

Electrical Measurement and Source Accuracy for Additel's ADT672

ADT672 electrical pressure guide 

 

 

 

 


Intech IN-GEN Calibrator

Intech Instruments IN-GEN Calibrator

The IN-GEN by Intech Instruments is a battery operated, hand held, multifunction generator used in conjunction with a multimeter to simulate RTD's, thermocouples, mA, mV and V signals. 

  

 

 

 

 

Features
Specifications

  • Simulates - RTD's, mA, T/C's, mV & V
  • Compact
  • Battery powered - 9 volt battery
  • Low cost
  • Outputs instrument signals
  • Use with our own multimeter 

Output - Resistance
50-150Ω Simulating DIN, Pt100, -100-100°c
  - Milliamps 0-20mA / 320Ω Max - Simulating 0-20mA and 4-20mA signals
  - Millivolts 0-100mV / 20mA max load - Simulating all Thermocouple signals
  - Volts 0-8V / 20mA max load - Simulating 0-5V and 1-5V signals
Power Supply 9V battery
EMC Compliances
Emissions EN55022-A. Immunity EN50082-1.
<1% Effect FSO Typical
Operating Temperature & Humidity
0-50°c [storage temp: -10 to 70°c]
5-85% RH Max. Non condensing
Dimensions   L=128 x W=67 x H=58mm

Additel ADT761-LLP/D Automated Pressure Calibrators

Additel ADT761 Pressure Calibrator

  • Fully automated pressure calibrator with built-in pressure generator / controller to as high as 15 psi  (1 bar) or as low as 0.01 Pa (0.00004 inH2O) 0.02%FS/
  • 0.05%FS accuracy 
  • Dual pressure modules 
  • Built-in filter and liquid trap with venting system prevents contamination of the calibrator 
  • Portable (12.4 lb)  

 

With a built-in high performance electronic pump and precision pressure controller, Additel's 761 series portable automated pressure calibrators provide a turn-key solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory. In a portable package, this calibrator can automatically generate pressures  from 100hPa to 1200hPa.

The 761-BP is specially designed for low pressure calibration . With a quartz pressure sensor , the accuracy of 761-BP can achieve 0.01%FS accuracy .

In addition to the pressure generation, control, and measurement capabilities, the 761 also features HART communication capability, supplies 24V loop power, and reads the current or voltage produced by the pressure transducers. The 761 is a state of the art automated pressure calibrator which brings automated pressure calibration to the field.

Features
Specifications
Pressure Range
Ordering Info
Video Demo

Pressure Range 
Pressure generated by built-in pump and controlled automatically from 90% vacuum to 15 psi (40 bar)
Pressure measured with external pressure modules (160 series) to 10,000 psi (700 bar)
Accuracy (Fully temperature compensated)  0.01%FS(ADT761-BP)
0.02%FS
0.05%FS (ADT761-LLP)
 
Control Stability
<0.005%FS
ADT761-LLP: <0.05Pa (0.0002 in H2O)
 
Contamination prevention system
Built-in filter and liquid trap with venting system prevent contamination of the calibrator 
Solid particles can be blocked by built-in filter
A small amount of Liquid can be collected by the built-in liquid trap
Both solid particles and liquid can be blown out through the venting system

 

Automation and Test Program
Fully Automated pressure calibration
Task preset and auto run
Auto step

Easy to Use
User friendly interface 
Intuitive icon driven menu structure

Sourcing and Measuring electrical signals
Measure mA or V with 0.01% RD + 0.005%FS accuracy
Source/sink 0 to 22mA current
24 VDC loop power supplied to pressure transmitter during test
Automated switch test

Misuse Protection
Up to 30V misuse protection  on any two sockets

Display
7" LCD color screen (800X480)

Documenting and data logging
Task management capability
Internal memory stores 200 tasks
Download tasks and upload results

HART Communication capability
Support HART instrumentation

Rechargeable battery: 
Rechargeable battery with up to 8 hours operation between charges

Leak testing: 
Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks

Pipeline Protection: 
Special design the pipeline layout to avoid possible blockage and leakage

Portable: 
Only 12.4 lb

Multi Lingual Interface
English, German, French, Italian, Spanish, Portuguese, Simplified Chinese (Traditional Chinese, Japanese and Russian are available per request)

NIST Traceable: 
NIST traceable calibration with data (included) 

Control Stability
<0.005%FS; 
ADT761-LLP: <0.05Pa (0.0002 in H2O)
 
Pressure Connections
G1/8 Female on calibrator   Two 1/4NPT(or 1/2NPT, 1/4BSP, M20×1.5) female hand-tight connectors on the external pressure manifold (included)

External Pressure Module Connection
External pressure module connector

Electrical Connection
0.156 inch (Ø4mm) banana sockets

Documenting and data logging 
Task management capability 
Internal memory stores 200 tasks 
Download tasks and upload results

Display
7" LCD color screen (800×480)
Display rate: 5 readings per second
Pressure Units
Pa, kPa, MPa, psi, bar, mbar, inH2O 4°C, mmH2O 4°C, inH2O 20°C, mmH2O 20°C, inHg 0°C, mmHg 0°C, kgf/cm2
 

Power
Battery: Rechargeable Li-ion Polymer battery (included)
Li-Battery working time: ~8 hours
Recharge time: ~3 hours
External Power: 110/220V Power adapter (DC 27 V) (Included)

Environmental Specification
Operating temperature: 32°F to 122°F (0°C to 50°C) 
Compensated Temperature: 32°F to 122°F (0°C to 50°C)
Storage temperature: -20°C to 60°C 
Humidity: <90%, non-condensing

European Compliance
CE Marked

Communication
RS232 (DB9/F, environmentally sealed)
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data length: 7 Bits, 8 Bits 
Stop bit: 1 Bit, 2 Bits 
Address: from 1 to 121

Dimension  11.65" X 7.32" X 7.09"(296mm X186mm X180mm)

Weight  12.4 lb (5.6 kg)

Warranty 18 months

Pressure Range

 Type   Model  Pressure Range  Pressure Module 1  Pressure Module 2
Range Accuracy Range Accuracy
 Low /
 Differential
 Pressure  
 ADT761-LLP
 -25 to 25 mbar
(-10 to 10 in H2O)
-2.5 to 2.5 mbar
(-1 to 1 in H2O)
0.05%FS
 -25 to 25 mbar
(-10 to 10 in H2O)
0.05%FS
 ADT761-D 
-0.95 to 1 bar
(-13.5 to 15 psi)
-25 to 25 mbar
(-10 to 10 in H2O)
0.05%FS
-0.95 to 1 bar
(-13.5 to 15 psi)
0.02%FS

* One year accuracy (including yearly stability) except ADT761-LLP which is 0.05%FS calibration accuracy and 0.05%FS yearly stability.

* * Additel 761 calibrators support 160 series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.025%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specification refer to 160 series pressure modules datasheet.

Electrical Measurement and Source Accuracy

Range  Resolution  Accuracy 
 Voltage Measurement ±30.0000v 0.1mV ±[0.01%RD + 0.005%FS]
 Current Measurement   ±30.0000v  0.1UA  ±[0.01%RD + 0.005%FS]
 Current Source  0.000 to 22.000mA   1uA  ±[0.02%RD + 0.005%FS]
 On-Off Measurement   if the switch has detective voltage, the range is from 3V to 24V
 DC 24v ouput  24V ± 0.5V, max: 50mA

  

Additel ADT761 Ordering Guide 

 

 

 

 

 

 

 

 

ACCESSORIES [included]

 Code      Description  Qty 
 ADT106   External Pressure Manifold [except ADT761-LLP]  1 pc 
 9618   110V / 220V external power adapter   1 pc
 9722  Chargeable Li-ion battery 1 pc
 9022  Test leads for calibrator 1 sets
 9020  Short circuit cable 1 set
 9907  Carry case for ADT761 calibrator and accessories 1 pc
 9060  Pressure module connection cable 1 pc
 O-rings [except ADT761-LLP] 20 pcs
 Manual 1 pc
 Tools 1 set
 Hose 2 pc
 NIST traceable Calibration Certificate 1 pc

 

ACCESSORIES [optional]

  Code   Description 
  ADT100-761-4N   Hose test kit, 5 feet flexible hose, 04mm tube to 1/4NPT hand-tight quick connector
  ADT100-761-4B  Hose test kit, 5 feet flexible hose, 04mm tube to 1/4BSP hand-tight quick connector
  ADT106-N  External Pressure Manifold [with two 1/4NPT hand-tight quick connectors]
  ADT106-B  External Pressure Manifold [with two 1/4BSP hand-tight quick connectors]
  ADT106-M  External Pressure Manifold [with two M20X1.5 hand-tight quick connectors]
  ADT160  Pressure modules [please check Additel AST160 datasheet]
  9060  Pressure module connection cable

APCS FC051 Field Calibrator

APCS FC051 Field CalibratorField Calibrator for high accuracy that is a portable signal source by A.P.C.S

The APCS Field Calibrator combines a selft-contained process signal source together with a 2-wire transmitter simulator in one pocket sized instrument.

Built in 9V batteries, dry or rechargeable combined with compact size make this calibrator ideal for use in the field - an economical addition to the toolbox of every instrument technician.

Designed for maximum accuracy and ease of handling the FC051 features a 3.5 digit, 10mm high LCD display which provides direct read-out of mV or mA in sink or source mode. Output range is 0-22mV and 0-2200mV with display readability of 0-19.99mA and 0-2200mV. The display also provides LOW BATTERY indication and a mV sign when in mV output mode.

 

 

 

Specifications
Configuration
Ordering
Download

Size  110 x 66 x 70 mm 
Weight  Dry Cell 0.272kg / Nickel-Mh 0.290kg 
Case Material  High-impact polystyrene 
Accuracy  ±0.4% FS or  ± 1 digit
Ambient temp effect ±0.1% /°c
Operating temp range 0 to 50°c
Storage temp range -20 to +50°c
Display 3.5 digit LCD 10mm character hegith
Electromagnetic compatibility

complies with AS/NZS 4251.1 [EN 50081.1]

Current Output       Source range 0 - 22.00mA [0-50mA optional] 
          Sink range 3 - 23.00mA [3-50mA optional]  
Output load  
Source 0 - 800@ 
Sink Vs-6 [@
        0.02
Resolution  0.01mA 
Max Loop supply Voltage  40V 
Millivolt Output   Range 0 - 2200mV 
 Resolution 1mV 
    Minimum Load  10k@ 
  Source Impedance 100k@ 
Battery Life at full continuous output  Heavy Duty 9V 4hrs 
Alkaline 9V 8hrs 
 Ni-Mh 6hrs 
External power source  26Vdc / 30mA via 3.5mm phone plug tip [+] 

 

APCS FC051 Calibrator

  1. Red positive terminal [+] 

  2. Black switch [-sc]

  3. Selector switch for mA or mV output 

  4. Adjust span zero

  5. Switch to change from Span to Zero

  6. Blue negative switch [-sk]

  7. On switch

  8. LCD display

  9. 3.5mm plug socket

  10. Precision 10 turn potentiometer

FC051 Order Codes

Additel ADT761-L/M/H Automated Pressure Calibrators

Additel ADT761 Pressure Calibrator

  • Fully automated pressure calibrator with built-in pressure generator / controller to as high as  600psi (401 bar) 
  • 0.02%FS accuracy 
  • Dual pressure modules 
  • Built-in filter and liquid trap with venting system prevents contamination of the calibrator 
  • Portable (12.4 lb)  

 With a built-in high performance electronic pump and precision pressure controller, Additel's 761 series portable automated pressure calibrators provide a turn-key solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory. In a portable package, this calibrator can automatically generate pressures from 90% vacuum to 600 psi (40 bar) with 0.005% FS pressure control stability and 0.02% FS accuracy. To improve the calibrator accuracy, two pressure modules with differing ranges are built-in and integrated with the internal pump and controller.

With optional external pressure modules (160 series), the 761 can measure pressures up to 10,000 psi (700 bar) with 0.025%FS accuracy. In addition to the pressure generation, control, and measurement capabilities, the 761 also features HART communication capability, supplies 24V loop power, and reads the current or voltage produced by the pressure transducers. The 761 is a state of the art automated pressure calibrator which brings automated pressure calibration to the field.

 

Features
Specifications
Pressure Range
Ordering Info
Video Demo

Pressure Range
Pressure generated by built-in pump and controlled automatically from 90% vacuum to 600 psi (40 bar)
Pressure measured with external pressure modules (160 series) to 10,000 psi (700 bar) 
Accuracy (Fully temperature compensated) 0.02%FS
 
Control Stability
<0.005%FS
 
Contamination prevention system
Built-in filter and liquid trap with venting system prevent contamination of the calibrator 
Solid particles can be blocked by built-in filter
A small amount of Liquid can be collected by the built-in liquid trap
Both solid particles and liquid can be blown out through the venting system
 
Automation and Test Program
Fully Automated pressure calibration
Task preset and auto run
Auto step
 
Easy to Use
User friendly interface 
Intuitive icon driven menu structure
 
Sourcing and Measuring electrical signals
Measure mA or V with 0.01% RD + 0.005%FS accuracy
Source/sink 0 to 22mA current
24 VDC loop power supplied to pressure transmitter during test
Automated switch test
 
Misuse Protection
Up to 30V misuse protection  on any two sockets
 
Display
7" LCD color screen (800X480)
 
Documenting and data logging
Task management capability
Internal memory stores 200 tasks
Download tasks and upload results
 
HART Communication capability
Support HART instrumentation
 
Rechargeable battery:
Rechargeable battery with up to 8 hours operation between charges
 
Leak testing: 
Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks
 
Pipeline Protection: 
Special design the pipeline layout to avoid possible blockage and leakage
 
Portable:  Only 12.4 lb
 
Multi Lingual Interface
English, German, French, Italian, Spanish, Portuguese, Simplified Chinese (Traditional Chinese, Japanese and Russian are available per request)
 
NIST Traceable: 
NIST traceable calibration with data (included) 

Control Stability
<0.005%FS; 

Pressure Connections
G1/8 Female on calibrator  
Two 1/4NPT(or 1/2NPT, 1/4BSP, M20×1.5) female hand-tight connectors on the external pressure manifold (included)
 

External Pressure Module Connection
External pressure module connector

Electrical Connection
0.156 inch (Ø4mm) banana sockets
 

Documenting and data logging 
Task management capability 
Internal memory stores 200 tasks 
Download tasks and upload results

Display
7" LCD color screen (800×480)
Display rate: 5 readings per second
 
Pressure Units
Pa, kPa, MPa, psi, bar, mbar, inH2O 4°C, mmH2O 4°C, inH2O 20°C, mmH2O 20°C, inHg 0°C, mmHg 0°C, kgf/cm2
 

Power
Battery: Rechargeable Li-ion Polymer battery (included)
Li-Battery working time: ~8 hours
Recharge time: ~3 hours
External Power: 110/220V Power adapter (DC 27 V) (Included)

Environmental Specification:
Operating temperature: 32°F to 122°F (0°C to 50°C) 
Compensated Temperature: 32°F to 122°F (0°C to 50°C)
Storage temperature: -20°C to 60°C 
Humidity: <90%, non-condensing

European Compliance:
CE Marked

Communication
RS232 (DB9/F, environmentally sealed)
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data length: 7 Bits, 8 Bits 
Stop bit: 1 Bit, 2 Bits 
Address: from 1 to 121

Dimension 11.65" X 7.32" X 7.09"(296mm X186mm X180mm)

Weight: 12.4 lb (5.6 kg)

Warranty: 18 months 

Pressure Range

 Type   Model  Pressure Range  Pressure Module 1  Pressure Module 2
Range Accuracy Range Accuracy
 Low /
 Differential
 Pressure  
 ADT761-L
 -25 to 25 mbar
(-10 to 10 in H2O)
-2.5 to 2.5 mbar
(-1 to 1 in H2O)
0.05%FS
 -25 to 25 mbar
(-10 to 10 in H2O)
0.05%FS
 ADT761-M
-0.95 to 1 bar
(-13.5 to 15 psi)
-25 to 25 mbar
(-10 to 10 in H2O)
0.05%FS
-0.95 to 1 bar
(-13.5 to 15 psi)
0.02%FS
ADT761-H
-0.90 to 40 bar
(-13 to 600 psi)
-0.95 to 2.5 bar
(-13 to 35 psi)
0.02%FS
0 to 40 bar
(0 to 600 psi)
0.02%FS

* One year accuracy (including yearly stability) except ADT761-LLP which is 0.05%FS calibration accuracy and 0.05%FS yearly stability.

* * Additel ADT761 calibrators support ADT160 series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.025%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. 

Electrical Measurement and Source Accuracy

 Range  Resolution  Accuracy 
 Voltage Measurement ±30.0000v 0.1mV ±[0.01%RD + 0.005%FS]
 Current Measurement   ±30.0000v  0.1UA  ±[0.01%RD + 0.005%FS]
 Current Source  0.000 to 22.000mA   1uA  ±[0.02%RD + 0.005%FS]
 On-Off Measurement   if the switch has detective voltage, the range is from 3V to 24V
 DC 24v ouput  24V ± 0.5V, max: 50mA

  

Additel ADT761 Ordering Guide 

 

 

 

 

 

 

 

 

ACCESSORIES [included]

 Code   Description  Qty 
 ADT106   External Pressure Manifold [except ADT761-LLP]  1 pc 
 9618   110V / 220V external power adapter   1 pc
 9722  Chargeable Li-ion battery 1 pc
 9022  Test leads for calibrator 1 sets
 9020  Short circuit cable 1 set
 9907  Carry case for ADT761 calibrator and accessories 1 pc
 9060  Pressure module connection cable 1 pc
 O-rings [except ADT761-LLP] 20 pcs
 Manual 1 pc
 Tools 1 set
 Hose 2 pc
 NIST traceable Calibration Certificate 1 pc

 

ACCESSORIES [optional]

 Code 
 Description 
 ADT100-761-4N 
 Hose test kit, 5 feet flexible hose, 04mm tube to 1/4NPT hand-tight quick connector
 ADT100-761-4B
 Hose test kit, 5 feet flexible hose, 04mm tube to 1/4BSP hand-tight quick connector
 ADT106-N
 External Pressure Manifold [with two 1/4NPT hand-tight quick connectors]
 ADT106-B
 External Pressure Manifold [with two 1/4BSP hand-tight quick connectors]
 ADT106-M
 External Pressure Manifold [with two M20X1.5 hand-tight quick connectors]
 ADT160
 Pressure modules [please check Additel AST160 datasheet]
 9060
 Pressure module connection cable

From our General Manager

We have all your Pressure, Instrumentation and Gas Detection in the one place.

Craig Colhoun

Craig Colhoun

General Manager

Would you like to know how we can help you?

Request more Information